Conductors, Conduit & Raceways

The core install chain: Table 310.16 ampacity, conductor sizing, voltage drop, derating and bundling adjustments, conduit and box fill, bending offsets, cable tray fill, pulling tension, support spacing and burial depth.

16 calculators · NEC 2026 & 2023 dual citations

NEC 2026 / 2023

Wire Gauge Calculator

Find the minimum conductor size (AWG/kcmil) for any electrical load per NEC §310.16. Supports 60°C, 75°C, and 90°C ratings, continuous loads (125%), and parallel runs.

Open calculator
NEC 2026 / 2023

Voltage Drop Calculator

Calculate AC/DC voltage drop and select conductor size per NEC §210.19 and §215.2 recommendations (3% branch, 5% overall). Uses Chapter 9 Table 9 resistance.

Open calculator
NEC 2026 / 2023

Wire Ampacity Chart & Reference Lookup

Interactive NEC Table 310.16 & Table 310.17 wire ampacity chart with ambient temperature and conduit bundling adjustment calculators.

Open calculator
NEC 2026 / 2023

Conductor Derating Calculator

Calculate adjusted conductor ampacity when bundling more than 3 current-carrying conductors (§310.15(C)(1)) and correcting for elevated ambient temperatures (§310.15(B)(1)).

Open calculator
NEC 2026 / 2023

Conduit Fill Calculator

Calculate raceway fill percentage and minimum conduit size per NEC Chapter 9 Tables 1, 4, and 5. Supports EMT, IMC, RMC, PVC-40, PVC-80, ENT, FMC, and LFMC with mixed wire sizes.

Open calculator
NEC 2026 / 2023

Box Fill Calculator

Calculate electrical junction box and device box fill volume in cubic inches per NEC §314.16. Covers conductors, devices, internal clamps, studs, and grounding wires.

Open calculator
NEC 2026 / 2023

Pull & Junction Box Sizing Calculator

Determine minimum pull and junction box dimensions for conductors #4 AWG and larger per NEC §314.28. Covers 8× straight pulls, 6× angle pulls, and U-pulls.

Open calculator
NEC 2026 / 2023

Conduit Body & Mogul LB Calculator

Size standard and Mogul conduit bodies (LB, LL, LR, T, C), cubic inch volume for < #4 AWG, and 6×/8× rules for ≥ #4 AWG per NEC §314.28.

Open calculator
NEC 2026 / 2023

Conduit Bending Calculator

Calculate offset multipliers, shrink, 90° stub-up take-up, 3-point and 4-point saddles, rolling offsets, and 360° bend limits for EMT & RMC.

Open calculator
NEC 2026 / 2023

Cable Tray Fill Calculator

Calculate minimum cable tray width and allowable fill area for ladder, ventilated, and solid bottom trays per NEC Article 392 and §392.22.

Open calculator
NEC 2026 / 2023

Wire Pulling Tension Calculator

Calculate conduit wire pulling tension, bend multiplier, Sidewall Bearing Pressure (SWBP), and pulling grip limits per IEEE 576 & NEC Ch. 9.

Open calculator
NEC 2026 / 2023

Conduit & Cable Support Spacing Lookup

Lookup maximum support strapping intervals and distance from boxes for NM, MC, EMT, RMC, PVC, and FMC per NEC Chapters 3.

Open calculator
NEC 2026 / 2023

MC Cable Connector Spacing & Gutter Sizing

Calculate knockout center-to-center spacing for MC cable connectors, locknut clearances, and panel wire-bending gutters per NEC §330.30 & §312.6.

Open calculator
NEC 2026 / 2023

Tap Conductor Rules Calculator

Calculate 10-foot (1/10th ampacity) and 25-foot (1/3rd ampacity) feeder tap conductor sizing and termination protection per NEC §240.21(B).

Open calculator
NEC 2026 / 2023

Underground Duct Bank Ampacity

Calculate underground electrical duct bank ampacity, mutual heating derate factors, soil RHO, and conduit configurations per NEC Annex B.

Open calculator
NEC 2026 / 2023

Underground Burial Depth Calculator

Find minimum underground burial depth (cover) per NEC §300.5 Table 300.5. Covers Direct Burial (UF-B), Rigid Metal Conduit (RMC), PVC Schedule 40/80, residential GFCI circuits, and driveways.

Open calculator